²úÆ·¹æ¸ñ£º
²úÆ·½éÉÜ£º
ɸѡ×ÓÆç¹ÜÓÃÓÚɸѡ³äÆøÁ÷ÌåÖпÉÄܶÂÈû³äÆø¶Ë¿ÚµÄ¹ÌÌ壬»ò·ÅÖÃÔÚÇò×ùÉÏÒÔ·ÀÖ¹ÇòÐÎÃÜ·â¡£ÔÚÐí¶àÁ¬ÐøÓ͹ܹ¤×÷ÖУ¬¿ÉÄÜ»áÔÚÁ÷Ì幩ӦÖгöÏÖÒÔǰ¹¤×÷¹ý³ÌÖеÄɳ×Ó»òÆäËû¹ÌÌå¡£
ÌØµãÓëÓÅÊÆ£º
ɸѡ×ÓÆç¹ÜÀïÃæ·ÅÖÃÁ½¸öÏß°ü¹üµÄ¹ýÂËÆ÷¡£½ðÊôË¿°ü¹ü¿ÉÒÔ±£»¤½ðÊôË¿Íø¹ýÂËÆ÷£¬²¢É¸³ö´ó¿ÅÁ£¹ÌÌå¡£±»±ÃË͵½Ó͹ܵÄÁ÷Ìåͨ¹ý¹ýÂËÆ÷ɸ³ö¹ÌÌ塣ɸѡ×ÓÆç¹ÜÅ䱸ÁËÒí×´½ÓÍ·£¬±ãÓÚ°²×°±Ã¹Ü·¡£¹ýÂËÆ÷ÊÇ63΢Ã×£¬¿ÉÒÔ×èֹСÐ͹ÌÌå¡£ ¶ÂÍ·±êÓмýÍ·À´Ö¸Ê¾Á÷ÌåÁ÷¶¯µÄ·½Ïò¡£
²úÆ·×é×°£º
1.ÓÃÓÍÖ¬ÇáÇáͿĨËùÓÐÏß·¡£
2.½«¶ÂÍ·(9)·ÅÔÚ»¢Ç¯ÖС£
3.½«Weco×é¼þ(3)µÄWecoĸͷ×é×°µ½¶ÂÍ·ÉÏ¡£
4.½«¹Ü½ÓÍ·(7)×é×°µ½¶ÂÍ·(9)ÉÏ¡£
5.½«¹ýÂ˹Ü×é¼þ(5)×é×°µ½¹Ü½ÓÍ·(7)ÉÏ¡£
6.½«3/4"¹ÜÈû(2)°²×°µ½¹ýÂ˹Ü×é¼þ(5)ÖС£
7.½«ÃÜ·âȦ(1)°²×°µ½ÁªÖáÆ÷(8)ÖС£
8.½«ÁªÖáÆ÷(8)·ÅÖõ½¹ýÂ˹Ü×é¼þ(5)£¬²¢½«ÁªÖáÆ÷(8)Óë¶ÂÍ·(9)Á¬½Ó¡£
9.½«¶Ì½Ó(6)·ÅÖõ½¹ýÂ˹Ü×é¼þ(5)£¬²¢Á¬½ÓÖÁÁªÖáÆ÷(8)¡£
10.½«ÃÜ·âȦ(1)°²×°µ½Ð¨Ðμþ(4)ÖС£
11. ½«Ð¨Ðμþ(4)×é×°µ½¶Ì½Ó(6)ÖС£
12.½«Weco×é¼þ(3)µÄWeco¹«Í·×é×°µ½Ð¨Ðμþ(4)ÖС£
¹ØÓÚ¶¦ºãʯÓÍ
ÈôÐèÒª¹ºÂò¾®Ï²úÆ·»òÐèÒªÁ˽â²úÆ·Ïêϸ²ÎÊý¼°Ïà¹ØÒÉÎÊ£¬¿ÉÖ±½Ó½øÈ붦ºãʯÓ͹ÙÍø×ÉÑ¯ÍøÕ¾¿Í·þ»òÕß²¦´òÏúÊÛÈÈÏß18000522697¡£
ËÄ´¨¶¦ºãʯÓÍ»úеÉ豸ÓÐÏÞ¹«Ë¾(http://www.hqbmvx.cn)ÊÇÒ»¼ÒÓµÓнø³ö¿Ú¾ÓªÈ¨£¬³¤ÆÚ´ÓʹúÄÚÍâʯÓÍÌìÈ»ÆøÉ豸ºÍÅä¼þµÄרҵÏúÊÛ¹«Ë¾¡£¶¦ºãʯÓ͹«Ë¾×ܲ¿ÉèÔÚËÄ´¨³É¶¼£¬ÔÚ¼ÓÄôó´ó²»Áе߸çÂ×±ÈÑÇÊ¡³ÉÁ¢ÁË·Ö¹«Ë¾¡£ÎÒ¹«Ë¾Óë¶à¼ÒÊÀ½çÖªÃûÖÆÔì³§É̽¨Á¢Á˽ôÃܵĺÏ×÷¹ØÏµ¡£
×¢£º¸ÃÎÄÕÂÓɶ¦ºãʯÓͱàÒ룬ת·¢Ðë×¢Ã÷³ö´¦¡£
¸½Ó¢ÎÄÔÎÄ£º
Baker Screen Sub Manifold
Product Family No. H34018
Introduction
The Screen Sub Manifold is used to screen out solids in the Inflation fluid that might plug the inflation ports or lodge on a ball seat preventing a setting ball form sealing. In many coiled tubing jobs there may be sand or other solids in the fluid supply from previous jobs.
Features/Benefits
The Screen Sub Manifold houses two wire wrapped filters inside. The wire wrapping protects the wire mesh filter and also screens out large particles. Fluid being pumped to the tubing goes through the filters screening out solids. The Screen Sub Manifold is equipped with wing unions for ease of make up to the lines from the pumps. The filters are 63 micron so they will stop small solids. The Bottom Sub is marked with an arrow to indicate the direction of the fluid flow.
Assembly
1. Lightly coat all threads with grease.
2. Place Bottom Sub (9) in vise.
3. Make up Weco Female Sub portion of the Weco Union (3) to Bottom Sub.
4. Make up the Pipe Nipples (7) to the Bottom Sub (9).
5. Make up the Filter Tube Assemblies (5) to the Pipe Nipples (7).
6. Install the 3/4 Pipe Plugs (2) into the Filter Tube Assemblies (5).
7. Install the Seal rings (1) into the Coupling (8).
8. Slide the Coupling (8) over the Filter Tube Assemblies (5) and make up to the Coupling (8) to the Bottom Sub (9).
9. Slide the Pup Joint (6) over the Filter Tube Assemblies (5) and make up to the Coupling (8).
10. Install the Seal Ring (1) into the Swedge (4).
11. Make up the Swedge (4) to the Pup Joint (6).
12. Make up the Weco male Sub portion of the Weco Union (3) to the Swedge (4).
¿Í»§Ö»ÐèÖ§¸¶²úÆ·¼Û¸ñ£¬ÎÞÐèÖ§¸¶ÈÎºÎÆäËû·ÑÓã¬Èç°ü×°·Ñ»òÔË·Ñ£¬ÇÒ²»ÉèÖÃÆð¶¨Á¿¡£
¶¦ºãËùÓвúÆ·Ìṩ°ëÄêµÄÖÊÁ¿±£Ö¤£¬¶¦ºã´úÀíÆ·ÅÆ¿ÉÌṩ1ÄêµÄÖÊÁ¿±£Ö¤¡£
¼ÙÈçijЩ²úÆ·²»·ûºÏÐèÇó£¬ÔÚ±£Ö¤Íâ°ü×°ÍêÕûµÄǰÌáÏ£¬¶¦ºã½«°²ÅÅÍË»õ²¢ÇÒ¿ìËÙ·¢»õ¡£
¶¦ºãËùÓÐÌṩµÄ²úÆ·¾ùÓµÓнøÆ·±¨ËÍ×ÊÁϺÍÔÆ·Ö¤Ã÷£¬±£Ö¤ÕýÆ·¡£